DR Master Stations

Description

Standard surface/flush/desk mount standard master stations are used to operate disabled refuge EVC systems up to 20-off outstations.

For more cost effective solutions - saving on equipment, installation, and space - compact master stations have the master station, the system controller, the monitored PSU and the backup batteries built into a sngle standard fire panel sized enclosure.

And for even greater savings combined master stations have all the features of compact master stations  combined with a disabled toilets alarm monitoring station built into a single standard fire panel sized enclosure.

Custom Units

Folknoll Group produce a range of standard desk/wall mount master stations for Disabled Refuge EVC systems with up to 20 outstations.

Further Information

DT7550.85 Remote Panel Indicator Kit for Disabled Refuge EVC Master Stations
Image of Remote Indicator Panel Kit
  • LCD display
  • Integral sounder
  • Mute button
  • Monitors up to 8–off toilets
  • Can be extended to 16-off toilets (see below)
  • Mounts inside compact disabled refuge EVC system master station
  • Please refer to Disabled Toilet Alarm systems
  • DT7550.85 Remote Panel Indicator Kit                                                
DT7550.86 Remote Indicator Panel Extension Kit for Above
Disabled Refuge Combined-Master-Station-10-Way
DR RA7805.01 Compact System Master Station 5-Way
Disabled Refuge RA7805.01 Compact-Master-Station-5-Way
  • Controls up to 5-off outstations
  • Master station, control system, battery backed PSU, in one unit
  • Fault Monitoring
  • I/O for BMS or other external systems
  • Matches standard fire panel size and quality.
  • Surface or semi flush mount
  • DR RA7805.01 Compact System Master Station 5-Way                       
DR RA7810.01 Compact System Master Station 10-Way
Disabled Refuge RA7810.01 Compact-Master-Station-10-Way
  • Controls up to 10-off outstations
  • Master station, control system, battery backed PSU, in one unit
  • Fault Monitoring
  • I/O for BMS or other external systems
  • Matches standard fire panel size and quality.
  • Surface or semi flush mount
  • DR RA7810.01 Compact System Master Station 10-Way                     
DR RA7705.01/05 Standard System Master Station 5-Way
Disabled Refuge RA7705 Master Station 5 Way
DR RA7710.01/05 Standard System Master Station 10-Way
Disabled Refuge RA7710 Master Station 10 Way
DR RA7715.01/05 Standard System Master Station 15-Way
Disabled Refuge RA7715 Master Station 15 Way
DR RA7720.01/05 Standard System Master Station 20-Way
Disabled Refuge RA7720 Master Station 20 Way